Ice maker runs but makes very small or thin ice cubes or slivers that melt quickly.
Advertisements
Possible Causes
Low water level in reservoir, Clogged water inlet screen, Misadjusted ice thickness sensor, Scale buildup on evaporator plate
How to Fix / Troubleshooting
Safety: Disconnect power and shut off water before servicing water components.
Steps to correct thin ice:
- 1. Check water level: Remove the bin and observe the reservoir during operation. If the level is low, clean the float or level sensor and ensure proper fill.
- 2. Clean inlet screen: Remove the supply line at the inlet valve and clean the screen to restore full flow.
- 3. Clean evaporator plate: Run a full cleaning cycle to remove scale from the plate. Heavy scale can cause ice to release prematurely, resulting in thin pieces.
- 4. Verify thickness sensor: Inspect the ice thickness sensor for proper position and cleanliness. Adjust only as specified in the service manual.