E05
Teka
Evaporator Temperature Sensor / Thermistor Fault
E05 error, ice maker stops mid-cycle, often during freeze stage
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted evaporator thermistor, Loose thermistor connection at control board, Damaged thermistor wiring harness
How to Fix / Troubleshooting
Safety first: Disconnect the appliance from mains before accessing internal components.
- Locate thermistor: The evaporator thermistor is usually clipped to the evaporator plate or tubing in the freezing compartment. Remove the front panel or bin to access it.
- Inspect physically: Check that the thermistor is firmly attached to the evaporator surface and not hanging loose. Look for cracked casing or corroded connectors.
- Test resistance: Disconnect the thermistor from the harness and measure its resistance with a multimeter at room temperature. Compare to the Teka service chart. If reading is open, shorted, or far out of spec, replace the thermistor.
- Check wiring to PCB: Trace the harness back to the main control board. Ensure the connector is fully seated and wires are not pinched or cut. Repair or replace the harness if damaged.
- Reset and test: After replacing the sensor, clear the error by unplugging for several minutes or using the reset function. Run a full ice cycle and confirm normal operation.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Evaporator Thermistor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements