E06
Teka
Harvest Sensor / Ice Thickness Sensor Fault
E06 error, ice maker does not harvest ice or stops at end of freeze cycle
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective ice thickness probe, Misaligned harvest sensor, Mineral buildup on sensor surface, Faulty wiring to control board
How to Fix / Troubleshooting
Safety first: Unplug the unit and allow any hot surfaces to cool before working near the evaporator.
- Clean the ice thickness sensor: Locate the metal or plastic thickness probe near the evaporator plate where ice forms. Use warm water and a soft cloth to remove scale and mineral deposits. Do not use sharp tools that can damage the probe.
- Check alignment: Ensure the sensor or probe is correctly positioned relative to the evaporator plate as per the manual. If bent or out of place, gently reposition it.
- Inspect wiring: Follow the sensor wires back to the control board. Look for loose connectors, broken insulation, or corrosion. Reseat connectors and repair any damaged wiring.
- Test sensor (if accessible): Some thickness sensors can be tested for continuity or resistance. Compare readings to Teka specifications. Replace the sensor assembly if readings are abnormal.
- Run a test cycle: Restore power and initiate a cleaning or test cycle if available. Observe whether the unit now proceeds into harvest without error.
Advertisements
Repair Difficulty