E16
Teka
Ambient Temperature Sensor Fault
E16 error, unit indicates low ambient temperature and stops ice production
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective ambient thermistor, Sensor located in cold airflow, Wiring harness damage, Control board misreading sensor
How to Fix / Troubleshooting
Safety first: Disconnect power before accessing sensor wiring.
- Check installation location: Ensure the ice maker is installed within the ambient temperature range specified by Teka (typically above 10–13°C). Very cold rooms can trigger this error.
- Locate ambient sensor: The ambient thermistor is usually near the air intake grille or behind the front panel. Inspect for damage or dislodging into a colder area.
- Test thermistor: Measure resistance at room temperature and compare to the Teka resistance chart. Replace the sensor if readings are out of range.
- Inspect harness: Follow the sensor wires to the control board, checking for pinched or broken conductors. Repair or replace as needed.
- Reset and test: After replacing the sensor, clear the error and verify that the unit runs normally in the correct ambient conditions.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ambient Thermistor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements