Display shows E10, unit cycles but ice production is extremely low
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety First: Refrigerant systems are sealed and require EPA-certified service. Do not attempt to cut or open refrigerant lines yourself.
- Step 1 – Basic checks: Ensure condenser coil is clean and fan is operating. Poor airflow can mimic low refrigerant symptoms.
- Step 2 – Observe frost pattern: With panels removed, briefly run the unit and inspect the evaporator plate. A partial frost pattern or only at the inlet may indicate a sealed system issue.
- Step 3 – Listen for compressor: Confirm the compressor runs steadily without short cycling.
- Step 4 – Call a professional: If E10 is present and airflow components are normal, contact a qualified refrigeration technician. They will check system pressures, locate leaks, and recharge with the correct refrigerant.
Operating the unit with a refrigerant fault can cause further damage. Disconnect power until serviced.