Possible Causes

Dirty condenser coil, High ambient temperature around unit, Restricted airflow at front grille, Partially scaled evaporator plate

How to Fix / Troubleshooting

Safety First: Unplug the unit before cleaning coils or moving the appliance.

  • Step 1 – Improve ventilation: Ensure the front grille is not blocked and there is adequate clearance around the unit per U-Line installation specs.
  • Step 2 – Clean condenser coil: Remove the front grille and vacuum dust and lint from the condenser fins and fan area.
  • Step 3 – Descale evaporator: If ice cubes are thin or irregular, run a cleaning cycle with U-Line approved ice machine cleaner to remove mineral deposits from the evaporator plate and water system.
  • Step 4 – Check ambient temperature: Verify the room temperature is within the recommended range (typically 50–100°F). Extremely hot rooms will reduce ice output.

If production remains low after cleaning and airflow correction, a refrigeration performance issue may exist and should be checked by a technician.