U-Line No Operation with Power Present

Unit has power (lights on) but will not run or start ice cycle

Advertisements

Possible Causes

Door switch stuck open, Bin full sensor stuck in "full" position, Control board locked in error state, Failed start relay on control

How to Fix / Troubleshooting

Safety First: Unplug the unit before testing switches or sensors.

  • Step 1 – Check door status: Ensure the door is fully closed and the switch operates (light turns off when closed, if applicable).
  • Step 2 – Inspect bin level sensor: Clean and realign the ice level sensor. Remove excess ice that may be blocking it.
  • Step 3 – Power reset: Unplug for 5–10 minutes to clear any control lockup, then restore power.
  • Step 4 – Test door switch: Use a multimeter to verify the door switch changes state when actuated. Replace if faulty.

If the unit still will not start, the main control board may be defective.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.