E19
Vestfrost Configuration / Parameter Error

Display shows E19; ice maker stops; unit may indicate a sensor calibration or configuration error after board replacement.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Main PCB replaced without proper configuration, Incorrect model code set in service menu, Corrupted EEPROM data, Incompatible replacement PCB

How to Fix / Troubleshooting

Safety: Disconnect power before opening the control compartment.

Steps to address E19:

  • Verify PCB part number: Confirm that the installed main control PCB matches the exact Vestfrost model and voltage of your ice maker.
  • Enter service mode: Follow the Vestfrost service manual to enter configuration mode via the keypad (button sequence varies by model).
  • Set model parameters: Check and correct parameters such as model code, ice thickness setting range, sensor type, and language according to the data label or service documentation.
  • Save and reboot: Save settings, exit service mode, disconnect power for 1–2 minutes, then restore power and verify that E19 clears.
  • Replace PCB if incompatible: If configuration cannot be completed or options do not match your model, the PCB may be incompatible and should be replaced with the correct Vestfrost board.

Note: Configuration steps are model-specific; consult Vestfrost technical documentation or a professional if unsure.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements