Viking
Compressor Start / Mechanical Fault
Loud humming or clicking from compressor area; ice maker not cooling properly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failing compressor, Defective start relay, Weak start capacitor, High head pressure from dirty condenser
How to Fix / Troubleshooting
Safety first: Disconnect power before accessing compressor components. Capacitors can retain charge; discharge safely.
- Step 1 – Clean condenser: Ensure the condenser coil is clean and airflow is unobstructed to reduce compressor load.
- Step 2 – Inspect start components: Remove the start relay and capacitor from the compressor. Test them with a multimeter/capacitance meter and replace if defective.
- Step 3 – Listen after repair: Restore power and observe startup. If the compressor still hums and clicks off, the compressor may be locked and require replacement by a sealed system technician.
Do not repeatedly reset a tripping breaker or run a locked compressor; this can cause further damage.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Compressor Start Relay