E11
Weasy
Ice Thickness Sensor / Probe Fault
E11 error; ice cubes are too thin or too thick and the unit cannot complete a normal cycle.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Misadjusted ice thickness probe, Scale buildup on thickness sensor, Failed thickness sensor switch, Loose probe wiring
How to Fix / Troubleshooting
Safety first: Disconnect power and allow the evaporator to warm slightly before touching any metal surfaces.
- Locate the ice thickness probe: On many Weasy models, a metal or plastic probe hangs near the evaporator plate or grid and senses the ice slab thickness during harvest.
- Clean the probe: Use a soft cloth and warm vinegar solution to remove mineral deposits from the probe surface. Rinse with clean water and dry.
- Check adjustment: Some probes are adjustable via a screw or bracket. Refer to the service manual for the correct gap between the probe and evaporator. Adjust if the gap is clearly too large or too small.
- Inspect wiring: Ensure the probe wires are intact and firmly connected to the control board.
- Test function: If accessible, manually move the probe to simulate ice contact and check for continuity change with a multimeter.
- Replace the ice thickness sensor/probe assembly if cleaning and adjustment do not resolve E11 or if the switch does not change state when actuated.