E15
Weasy
Control Board EEPROM / Firmware Fault
E15 error; internal memory or configuration error, unit may reset repeatedly or lose settings.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted EEPROM on main PCB, Power surge damage to control board, Incomplete firmware update (if applicable), Failed microcontroller
How to Fix / Troubleshooting
Safety first: Disconnect power before accessing the control board.
- Power cycle the unit: Unplug the ice maker for at least 5 minutes to allow capacitors to discharge, then plug back in and observe if E15 clears.
- Check for surge damage: Remove the control board cover and inspect for burn marks, swollen components, or a burnt smell.
- Verify stable power: Use a surge protector or line conditioner if your mains supply is unstable. Avoid sharing the outlet with heavy appliances.
- Factory reset: If the Weasy model supports it, perform a factory reset using the button combination described in the user manual.
- Replace the main control board if E15 persists after reset and there are signs of board damage or corrupted memory.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board (Weasy Ice Maker PCB)