E16
Weasy Ambient Temperature Sensor (Cabinet NTC) Fault

E16 error; ambient temperature sensor fault, unit may not start in very hot or cold rooms.

Advertisements

Possible Causes

Open or shorted ambient NTC sensor, Sensor dislodged from mounting location, Damaged sensor wiring, Faulty control board sensor input

How to Fix / Troubleshooting

Safety first: Unplug the unit before removing any covers.

  • Locate the ambient sensor: On many Weasy ice makers, a small NTC sensor is mounted near the air intake grille or behind the front panel.
  • Inspect sensor and wiring: Check that the sensor is intact and its wires are not pinched or cut.
  • Test resistance: Disconnect the sensor and measure resistance at room temperature. Compare to the Weasy NTC chart. Replace if open, shorted, or far out of range.
  • Secure mounting: Ensure the sensor is positioned where it can accurately sense room air, not touching hot components.
  • Replace the ambient temperature sensor if defective. If a new sensor does not clear E16, the main control board may be at fault.