E17
Weasy
Door / Bin Safety Switch Failure
E17 error; door or bin switch fault, unit will not run with door closed or reports door open when closed.
Advertisements
Possible Causes
Misaligned door switch actuator, Failed magnetic reed or micro switch, Broken switch bracket, Disconnected switch wiring
How to Fix / Troubleshooting
Safety first: Unplug the ice maker before working around the door or bin area.
- Locate the door/bin switch: On Weasy models, this may be a small plunger switch or a magnetic reed switch near the bin opening.
- Check alignment: Ensure the door or bin magnet/actuator lines up with the switch when closed. Adjust the bracket or door alignment if necessary.
- Test the switch: Remove the switch from its housing and test continuity with a multimeter while actuating it. Replace if it does not open/close properly.
- Inspect wiring: Verify the switch harness is intact and firmly connected to the control board.
- Replace the door/bin switch assembly if mechanical or electrical failure is found.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door / Bin Switch (Weasy Ice Maker)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements