Possible Causes

Misaligned door switch actuator, Failed magnetic reed or micro switch, Broken switch bracket, Disconnected switch wiring

How to Fix / Troubleshooting

Safety first: Unplug the ice maker before working around the door or bin area.

  • Locate the door/bin switch: On Weasy models, this may be a small plunger switch or a magnetic reed switch near the bin opening.
  • Check alignment: Ensure the door or bin magnet/actuator lines up with the switch when closed. Adjust the bracket or door alignment if necessary.
  • Test the switch: Remove the switch from its housing and test continuity with a multimeter while actuating it. Replace if it does not open/close properly.
  • Inspect wiring: Verify the switch harness is intact and firmly connected to the control board.
  • Replace the door/bin switch assembly if mechanical or electrical failure is found.