E17
Westinghouse Door Switch / Service Panel Switch Fault

E17 error; unit may indicate a door or panel open condition and refuse to run.

Advertisements

Possible Causes

Failed door interlock switch, Misaligned door or panel, Broken switch actuator tab, Damaged switch wiring

How to Fix / Troubleshooting

Safety: Unplug the unit before adjusting or replacing switches.

  • Locate switch: Identify the door switch or service panel switch near the bin door or access panel.
  • Check alignment: Ensure the door or panel fully depresses the switch plunger when closed. Adjust hinges or latch if needed.
  • Test switch: Disconnect the switch and test continuity with a multimeter while pressing and releasing the actuator. Replace if readings are inconsistent.
  • Inspect actuator: Look for broken plastic tabs or brackets that press the switch. Replace or repair as necessary.
  • Reassemble and test: Restore power and confirm the E17 code clears when the door/panel is properly closed.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.