Westinghouse Start Inhibit / Safety Interlock Condition

Ice maker will not start a cycle; display shows normal but nothing happens when Start is pressed.

Advertisements

Possible Causes

Door switch open, Bin full sensor indicating full, Float switch stuck high, Control board locked in error state

How to Fix / Troubleshooting

Safety: Unplug the unit before testing switches.

  • Check door and bin: Ensure the bin door is fully closed and the door switch actuates properly.
  • Verify bin not full: Empty the bin and confirm the bin full sensor is not blocked or stuck.
  • Inspect float: Check the water level float switch for free movement. Clean and reposition if stuck.
  • Reset control: Disconnect power for 5–10 minutes to clear any latched error. Restore power and attempt to start a cycle again.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Level Float Switch
Check Price on Amazon