Zanussi
No Ice Production Without Error Code
Ice maker does not produce any ice, but powers on and appears to run normally (no error code displayed).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Freezer temperature too high, Dirty condenser coil, Partially blocked water inlet, Ice thickness sensor out of calibration
How to Fix / Troubleshooting
Safety: Unplug the unit and close the water supply before cleaning or disassembly.
- Check temperature: Use a thermometer in the ice compartment. Zanussi ice makers typically need around -10°C to -18°C at the evaporator to form ice. If too warm, inspect condenser cleanliness and fan operation.
- Clean condenser: Vacuum and brush the condenser coil to improve heat rejection and cooling performance.
- Verify water supply: Confirm strong water flow at the inlet hose and clean the inlet filter. Replace any clogged external filters.
- Inspect ice thickness sensor: Clean and realign the sensor as per the service manual. Incorrect readings can cause premature harvest and no usable ice.
- Run diagnostics: If available, enter Zanussi diagnostic mode to test compressor, fans, pump, and valves individually. Replace any component that fails to operate.
Advertisements
Repair Difficulty
Medium
3/5
Advertisements