AEG No Power – Primary Supply Failure

Microwave display and controls are dead; no lights or response.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse, Faulty door switch, Failed mains filter, Defective control PCB

How to Fix / Troubleshooting

Safety first: Unplug the microwave before opening the cabinet. Internal fuses are not user-serviceable in some regions.

  • Step 1 – Verify outlet: Confirm the wall socket has power by testing with another appliance.
  • Step 2 – Check plug and cord: Inspect for visible damage. Replace if necessary.
  • Step 3 – Internal fuse: A technician can remove the cover, test the main fuse, and investigate the cause of any blown fuse before replacing it with the exact AEG-specified type.
  • Step 4 – Control board: If fuses and switches are good, the control PCB may have failed and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Internal Fuse
Check Price on Amazon