E2
Ambiano Secondary / Monitor Door Switch Fault

Microwave beeps and displays E2; cooking does not start or stops shortly after starting.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective monitor switch, Incorrect door switch alignment, Damaged door latch cam, Shorted wiring in door switch harness

How to Fix / Troubleshooting

Safety first: Unplug the microwave. High-voltage components inside can be lethal. If unsure, use a professional technician.

  • Check door operation: Open and close the door several times. Listen for distinct clicks from the switches. A missing or weak click can indicate a bad switch.
  • Access switch assembly: Remove the outer cover. Locate the door switch bracket on the side of the cavity where the latch hooks enter.
  • Inspect the monitor switch: The monitor switch is usually wired differently (often with a different colored wire). Look for signs of overheating or melting.
  • Test with a multimeter: Remove wires and test continuity according to the switch diagram printed on its body. Replace if it does not change state correctly when the door is opened/closed.
  • Check latch cam and bracket: Ensure the plastic latch cam that actuates the switches is not cracked or loose. Tighten screws or replace the latch bracket if worn.

Note: Door switch circuits are a safety system. All switches must be correctly installed and adjusted.