E6
Ambiano Control Panel / Keypad Communication Error

Microwave displays E6; keypad and display may freeze or respond erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose ribbon cable between keypad and control board, Corroded keypad contacts, Failed touch membrane, Faulty main control PCB

How to Fix / Troubleshooting

Safety first: Unplug the microwave before opening the cabinet.

  • Power reset: Unplug the unit for 5 minutes, then plug back in. Sometimes E6 is a transient control glitch.
  • Inspect keypad ribbon cable: Remove the control panel assembly (usually a few screws behind the top grille or side). Carefully disconnect and reconnect the flat ribbon cable from the keypad to the control board. Ensure it is fully seated and not damaged.
  • Check for moisture or contamination: Look for signs of liquid spills or steam damage behind the control panel. Dry the area thoroughly and clean light corrosion with isopropyl alcohol and a soft brush.
  • Test keypad: If certain buttons do not respond or trigger E6, the touch membrane may be failing. Replace the control panel/keypad assembly with an Ambiano-compatible part.
  • Replace control PCB: If the keypad is known good and E6 persists, the main control board may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5