E06
Amica Grill / Convection Temperature Sensor Fault

Microwave shows E06 and stops; grill or convection functions may be disabled.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted NTC temperature sensor, Damaged sensor wiring, Faulty connector on control board, Overheated grill element area

How to Fix / Troubleshooting

Safety: Unplug the microwave and allow it to cool fully.

  • Locate sensor: On Amica combination microwaves, the temperature sensor (NTC) is usually mounted on the top or rear of the cavity or near the grill element.
  • Inspect wiring: Check the sensor leads for heat damage or broken insulation. Ensure the connector at the control PCB is firmly seated.
  • Test sensor: With a multimeter, measure the resistance of the NTC at room temperature and compare with Amica service specifications (typically in the tens of kΩ). An open circuit or near-zero resistance indicates a faulty sensor.
  • Replace sensor: If defective, replace with the correct Amica temperature sensor. Route the wiring away from hot surfaces.
  • Clear error: After replacement, disconnect power for a few minutes to reset the control, then test grill/convection operation.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cavity Temperature Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements