Bauknecht Cavity Arcing / Waveguide Cover Damage

Microwave makes crackling, popping, or arcing noises inside the cavity during operation.

Advertisements

Possible Causes

Damaged or burnt mica waveguide cover, Food or grease buildup on cavity walls, Use of metal containers or foil, Exposed metal on cavity paint

How to Fix / Troubleshooting

Safety first: Stop the microwave immediately if you see sparks. Unplug before cleaning or inspection.

  • Step 1 – Remove metal objects: Ensure you are not using metal cookware, foil, or dishes with metallic trim.
  • Step 2 – Clean the cavity: Thoroughly clean the interior, especially around the waveguide cover (usually a small rectangular panel on the side wall). Remove all grease and food splatters.
  • Step 3 – Inspect waveguide cover: If the mica cover is burnt, cracked, or has holes, replace it with a genuine Bauknecht waveguide cover cut to the correct size.
  • Step 4 – Touch-up paint: If enamel is chipped exposing bare metal, use microwave-safe cavity touch-up paint to cover small spots (follow manufacturer instructions).
  • Step 5 – Test: After cleaning and replacing the cover, test with a cup of water. If arcing persists, have a technician inspect the magnetron and waveguide.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Waveguide Cover (Mica Plate)
Check Price on Amazon

We may earn a commission from links on this page.