Bauknecht
Cavity Arcing / Waveguide Cover Damage
Microwave makes crackling, popping, or arcing noises inside the cavity during operation.
Advertisements
Possible Causes
Damaged or burnt mica waveguide cover, Food or grease buildup on cavity walls, Use of metal containers or foil, Exposed metal on cavity paint
How to Fix / Troubleshooting
Safety first: Stop the microwave immediately if you see sparks. Unplug before cleaning or inspection.
- Step 1 – Remove metal objects: Ensure you are not using metal cookware, foil, or dishes with metallic trim.
- Step 2 – Clean the cavity: Thoroughly clean the interior, especially around the waveguide cover (usually a small rectangular panel on the side wall). Remove all grease and food splatters.
- Step 3 – Inspect waveguide cover: If the mica cover is burnt, cracked, or has holes, replace it with a genuine Bauknecht waveguide cover cut to the correct size.
- Step 4 – Touch-up paint: If enamel is chipped exposing bare metal, use microwave-safe cavity touch-up paint to cover small spots (follow manufacturer instructions).
- Step 5 – Test: After cleaning and replacing the cover, test with a cup of water. If arcing persists, have a technician inspect the magnetron and waveguide.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Waveguide Cover (Mica Plate)
Check Price on Amazon