E17
Bertazzoni Inverter Power Module Fault (Inverter Models)

Microwave shows E17 and the unit will not start; sometimes accompanied by a faint burning smell previously.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed inverter power module, Shorted magnetron drawing excessive current, Overheated inverter heat sink, Loose inverter harness

How to Fix / Troubleshooting

Safety first: Unplug the microwave. Inverter-based high-voltage systems operate at dangerous voltages and frequencies.

  • Step 1 – Do not continue to operate: If E17 appears and you noticed a burning smell earlier, stop using the microwave immediately.
  • Step 2 – Visual inspection: With the cover removed and power disconnected, locate the inverter module (metal-encased board near the magnetron). Look for burn marks or melted connectors.
  • Step 3 – Check cooling: Ensure that the inverter heat sink and surrounding area are not clogged with dust or grease.
  • Step 4 – Professional replacement: Inverter modules and associated magnetron testing should be performed by a qualified technician. The usual repair is replacement of the inverter module and, if necessary, the magnetron.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Inverter Power Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements