Bertazzoni Start Circuit / Safety Interlock Inhibit

Microwave interior light works and display is on, but pressing Start does nothing.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty Start button on keypad, Open door switch in start circuit, Control board input failure, Child lock engaged

How to Fix / Troubleshooting

Safety first: No high-voltage work is required for basic checks.

  • Step 1 – Check child lock: Look for a lock icon on the display. Follow the manual to disable the child lock feature.
  • Step 2 – Test other keys: See if other buttons respond (time setting, power level). If only Start is unresponsive, the keypad may be failing.
  • Step 3 – Door closure: Open and close the door firmly. If the control thinks the door is open, it will not start. Listen for distinct clicks from the door switches.
  • Step 4 – Keypad and switch testing (advanced): With power disconnected, test the Start key circuit and door switches with a multimeter. Replace the membrane keypad or door switch as needed.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Membrane Keypad
Check Price on Amazon

We may earn a commission from links on this page.