Possible Causes

Blown internal line fuse, Faulty power supply section on control PCB, Loose display connector, Failed display module

How to Fix / Troubleshooting

Safety: Unplug the microwave before opening the cabinet.

  • Step 1 – Check outlet: Confirm the outlet has power by plugging in another appliance.
  • Step 2 – Internal fuse: Remove the cabinet and locate the internal line fuse. Test for continuity and replace only with the same rating if blown. Investigate why it blew.
  • Step 3 – Inspect control board: Look for burnt components or bulging capacitors on the control PCB. Reseat any connectors to the display module.
  • Step 4 – Replace control PCB or display: If the power supply section is faulty or the display module is dead, replace the appropriate part using a Bomann-compatible assembly.