Bosch Door Alignment / Latch Failure

Microwave door does not close fully or pops open during operation.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Bent door hinges, Worn latch hooks, Misaligned cabinet, Obstruction on door seal

How to Fix / Troubleshooting

Safety: Unplug the microwave before adjusting or inspecting the door.

  • Check for obstructions: Inspect the door gasket and cavity front for food debris or foreign objects. Clean thoroughly.
  • Inspect hinges: Look for visible bending or looseness. Tighten accessible hinge screws from the front if possible.
  • Test closure: Close the door firmly and see if it latches with a solid click. If it springs back or pops open, the latch hooks may be worn.

If the door will not stay closed: Do not operate the microwave. The latch assembly or hinges need replacement or adjustment by a Bosch technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Door Hinge and Latch Assembly
Check Price on Amazon