Bosch Intermittent Door Interlock Contact

Microwave runs only when the door is slightly lifted or pressed; stopping when you release pressure on the door.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Worn or loose door hinges, Misaligned door latch hooks, Failing door interlock switch, Bent latch bracket inside cabinet

How to Fix / Troubleshooting

Safety: Unplug the microwave before inspection.

  • Check door alignment: Look at the gap around the door. If it is uneven or the door sags, the hinges may be loose. Tighten accessible hinge screws from the front if possible.
  • Inspect latch hooks: Open the door and gently move the plastic hooks. If they wobble excessively or are cracked, they may not reliably actuate the switches.
  • Avoid forcing the door: Do not continue to operate the microwave by holding or lifting the door; this can worsen the damage.

Next step: The internal latch bracket and switches likely need adjustment or replacement. Schedule service with a Bosch technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Door Interlock Switch Set
Check Price on Amazon

We may earn a commission from links on this page.