Possible Causes
Stuck primary door switch, Miswired door switch after previous repair, Shorted control relay on PCB, Bent door latch actuating switches incorrectly
How to Fix / Troubleshooting
Safety first: Unplug the microwave immediately. This is a serious safety issue related to the door interlock system.
Step-by-step checks:
- 1. Do not use the microwave: Operating in this condition can be dangerous. Keep it unplugged until repaired.
- 2. Inspect door latch: Check for visible damage or misalignment of the latch hooks.
- 3. Access door switches: Remove the cabinet and inspect the door switch assembly. Verify that each switch is wired according to the Daewoo wiring diagram. Correct any miswiring.
- 4. Test switches: Use a multimeter to test each switch for proper open/closed operation. Replace any switch that is stuck closed.
- 5. Check control relay: If switches are correct, the control board's power relay may be welded closed and require PCB replacement.
Recommendation: Due to the safety implications, have a qualified technician verify the repair.