Microwave displays F1 and may beep continuously; unit may not respond to keypad inputs.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Unplug the microwave before opening the control area.
Reset attempt:
- Unplug the unit for 10–15 minutes to fully discharge and reset the control.
- Plug back in and see if F1 reappears. If it does, proceed to inspection.
Control board inspection:
- Remove the control panel and visually inspect the PCB for burnt components, cracked solder joints, or corrosion.
- Ensure all connectors are firmly seated.
Resolution: If no external cause is found and F1 persists, the control board must be replaced. Match the Emerson model and part number exactly. If you are not comfortable transferring wiring and mounting the new board, contact a technician.
Repair Difficulty
Required Part
We may earn a commission from links on this page.