F9
Emerson
Exhaust Fan / Cooling System Error
Microwave displays F9 and will not start; may occur after long use or overheating.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed exhaust fan motor, Blocked exhaust duct, Fan relay failure on control board, Overheated fan winding
How to Fix / Troubleshooting
Safety first: Unplug the microwave.
Airflow check:
- For over-the-range Emerson models, verify that the external vent or recirculation path is not blocked.
- Clean grease filters and ensure they are properly installed.
Fan inspection:
- Remove the outer cabinet and locate the exhaust/cooling fan motor.
- Spin the fan blade by hand; if stiff or seized, replace the fan motor.
- Check wiring to the fan and test for voltage during a cook cycle (technician task).
If the fan motor is good but not receiving power, the control board fan relay may be defective and require replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Exhaust Fan Motor
Check Price on Amazon