F9
Emerson Exhaust Fan / Cooling System Error

Microwave displays F9 and will not start; may occur after long use or overheating.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed exhaust fan motor, Blocked exhaust duct, Fan relay failure on control board, Overheated fan winding

How to Fix / Troubleshooting

Safety first: Unplug the microwave.

Airflow check:

  • For over-the-range Emerson models, verify that the external vent or recirculation path is not blocked.
  • Clean grease filters and ensure they are properly installed.

Fan inspection:

  • Remove the outer cabinet and locate the exhaust/cooling fan motor.
  • Spin the fan blade by hand; if stiff or seized, replace the fan motor.
  • Check wiring to the fan and test for voltage during a cook cycle (technician task).

If the fan motor is good but not receiving power, the control board fan relay may be defective and require replacement.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Exhaust Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements