Emerson
Door Latch Engagement Failure
Microwave door will not stay closed or pops open during operation.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Worn door latch hooks, Weak or broken door springs, Misaligned door hinges, Damaged latch receptacle in cabinet
How to Fix / Troubleshooting
Safety first: Unplug the microwave.
Door inspection:
- Check the door hooks for rounding or cracks; they should engage firmly in the cabinet.
- Inspect hinges for looseness; tighten mounting screws if needed.
- Examine the latch receptacles in the cabinet for damage.
Repair: Replace worn latch hooks or the entire door latch assembly. If the cabinet latch receptacle is damaged, professional service is recommended.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Door Latch Assembly
Check Price on Amazon