Emerson Door Latch Engagement Failure

Microwave door will not stay closed or pops open during operation.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Worn door latch hooks, Weak or broken door springs, Misaligned door hinges, Damaged latch receptacle in cabinet

How to Fix / Troubleshooting

Safety first: Unplug the microwave.

Door inspection:

  • Check the door hooks for rounding or cracks; they should engage firmly in the cabinet.
  • Inspect hinges for looseness; tighten mounting screws if needed.
  • Examine the latch receptacles in the cabinet for damage.

Repair: Replace worn latch hooks or the entire door latch assembly. If the cabinet latch receptacle is damaged, professional service is recommended.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Door Latch Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements