E08
Fagor Turntable Motor / Rotation Feedback Error

Microwave shows E08 and will not start; sometimes accompanied by a humming noise before stopping.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Seized turntable motor, Broken or stripped turntable coupler, Jammed turntable support wheels, Faulty turntable motor wiring

How to Fix / Troubleshooting

Safety: Unplug the microwave before touching the turntable drive components.

User checks:

  • Remove the glass tray and roller ring. Clean any spilled food or debris from the cavity floor.
  • Inspect the plastic coupler in the center for cracks or melting.
  • Spin the coupler by hand; it should turn smoothly. If it is stiff or jammed, check for obstructions underneath.
  • Reinstall the roller ring and tray, ensuring they sit flat and centered.

Motor inspection (intermediate):

  • Unplug the unit and remove the bottom cover (if accessible on your Fagor model).
  • Locate the turntable motor and check for signs of overheating or water ingress.
  • Test the motor for continuity and proper resistance per Fagor specs.
  • Verify wiring connections are secure.

If the motor is seized or open-circuit, replace the turntable motor. Always ensure the correct rotation direction and shaft type for your model.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Turntable Motor
Check Price on Amazon