Microwave shows E10 and beeps; door appears closed but unit refuses to start.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Unplug the microwave before adjusting any mechanical parts.
Door inspection:
- Open the door and inspect the plastic latch hooks at the top/side. Look for cracks, bending, or wear.
- Close the door slowly and observe alignment with the cabinet; the door should close evenly without rubbing.
- Gently lift and lower the door to check for excessive hinge play.
Minor adjustments:
- Tighten any accessible hinge screws (on some Fagor models, hinges are accessible from the side or top once trim is removed).
- If the latch hook is slightly bent, it may be carefully realigned, but replacement is preferred if damaged.
Internal latch bracket (qualified):
- Remove the outer cover and locate the latch bracket that holds the door switches.
- Ensure the bracket is firmly secured and not cracked.
- Replace the latch bracket or door assembly if alignment cannot be restored.
Do not attempt to defeat the door safety system. If E10 persists, have a professional evaluate the door and latch system.
Repair Difficulty
Required Part