Fagor No Power – Primary Supply Failure

Microwave does not start at all; display is blank and no lights or sounds when door is opened.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal line fuse, Faulty power cord, Open thermal fuse on cavity, Failed line filter board

How to Fix / Troubleshooting

Safety: Unplug the microwave before any inspection.

Basic checks:

  • Verify the wall outlet has power by testing with another appliance.
  • Check the household circuit breaker or fuse for the microwave circuit.
  • Inspect the power cord for visible damage.

Internal fuse (qualified):

  • Remove the outer cover and locate the main line fuse near the power entry.
  • If the fuse is blown, investigate for short circuits (door switches, HV components) before replacing.
  • Replace only with the exact same rating and type specified by Fagor.

If the new fuse blows immediately, stop and have a technician diagnose the underlying fault.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Line Fuse
Check Price on Amazon