Fagor Membrane Keypad Wear

Microwave keypad buttons are unresponsive or require very hard pressing.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Worn membrane contacts, Cracked keypad overlay, Moisture damage to keypad, Damaged keypad ribbon cable

How to Fix / Troubleshooting

Safety: Unplug before working on the control panel.

Cleaning and test:

  • Clean the keypad surface with a soft, slightly damp cloth and dry thoroughly.
  • Test multiple keys; if only certain areas fail, the membrane is likely worn.

Repair:

  • Replace the membrane keypad or entire control panel assembly according to Fagor parts availability.

Membrane replacement involves carefully peeling and sticking the new keypad; avoid bending the ribbon cable sharply.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Membrane Keypad
Check Price on Amazon