Fisher & Paykel No Power / Dead Appliance

Microwave completely dead: no display, no lights, no response when buttons are pressed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal line fuse, Open thermal fuse on cavity, Faulty power cord, Failed main control PCB power supply

How to Fix / Troubleshooting

Safety first: Unplug the microwave before opening the cabinet. Internal components can be sharp and hazardous.

  • Check outlet and breaker: Verify that the outlet has power by plugging in another appliance. Check the household circuit breaker or fuse.
  • Inspect power cord: Look for visible damage to the cord. If damaged, the cord must be replaced.
  • Access internal fuse: Remove the outer cover (for countertop) or access panel. Locate the line fuse near the power cord entry or on the noise filter board. Test for continuity with a multimeter.
  • Replace blown fuse (with caution): If the fuse is blown, replace it only with the exact same rating specified by Fisher & Paykel. If the new fuse blows immediately, there is an underlying fault (shorted high-voltage component, shorted cord, etc.) that must be diagnosed by a technician.
  • Check thermal fuse: Locate the cavity thermal fuse and test for continuity. Replace if open.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Line Fuse
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements