Fisher & Paykel
Cavity Lamp Failure
Microwave interior light does not come on when the door is opened or during cooking, but the unit heats normally.
Advertisements
Possible Causes
Burned-out cavity lamp, Loose lamp socket, Open lamp wiring, Faulty lamp relay on control board
How to Fix / Troubleshooting
Safety first: Unplug the microwave before replacing the lamp. Glass can be hot and fragile.
- Access lamp: On many Fisher & Paykel models, the lamp is accessible by removing the top grille and a small lamp cover, or from the rear.
- Inspect and replace bulb: Remove the old bulb and inspect the filament. Replace with the exact type and wattage specified by Fisher & Paykel.
- Check socket and wiring: Ensure the socket is not burned or loose. Tighten connections as needed.
- Test operation: Reassemble and test. If the new bulb does not light, the control board lamp circuit may be faulty and require professional diagnosis.