Fisher & Paykel Door Interlock Switches Miswired or Stuck

Microwave interior light, fan, and turntable run when the door is closed, even without pressing Start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck relay on control board, Misadjusted or welded door switch contacts, Incorrectly installed door switch after prior repair, Shorted control board input

How to Fix / Troubleshooting

Danger: A microwave that runs with the door closed and no command is a serious safety hazard. Unplug it immediately.

  • Do not operate: Leave the unit unplugged until the fault is corrected.
  • Inspect door switches: With power disconnected, access the door switch assembly. Check for switches that are physically stuck or show signs of overheating.
  • Verify wiring: Compare the wiring to the Fisher & Paykel wiring diagram. Ensure each wire is on the correct terminal (COM, NO, NC).
  • Replace faulty switches: Replace any switch that does not change state correctly when the door is opened/closed.
  • Check control board relay: If switches and wiring are correct but the oven still runs when plugged in, the control board relay may be welded closed and the board must be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Door Interlock Switch Set
Check Price on Amazon