Galanz No Power – Primary Power Circuit Failure

Microwave does not start at all; display is blank and no lights or sounds when door is opened.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal line fuse, Faulty power cord, Failed line filter board, Open thermal fuse on cavity or magnetron

How to Fix / Troubleshooting

Safety: Unplug the microwave before inspection. Internal fuses are not user-serviceable in many regions; opening the cabinet may void warranties and expose you to high voltage.

Steps:

  • 1. Check outlet and breaker: Test the outlet with another appliance. Reset any tripped breakers.
  • 2. Inspect power cord: Look for cuts, burns, or loose plug blades. If damaged, have the cord or filter assembly replaced.
  • 3. Internal fuses and thermal cutouts: A technician should open the unit, test the line fuse and thermal fuses on the cavity and magnetron, and replace any open devices after identifying the cause.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Internal Line Fuse or Thermal Fuse
Check Price on Amazon

We may earn a commission from links on this page.