Grundig Membrane Keypad Wear or Failure

Microwave buttons do not respond or respond intermittently; some keys work, others do not.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Worn membrane contacts, Cracked keypad overlay, Damaged keypad ribbon cable, Liquid ingress into keypad

How to Fix / Troubleshooting

Safety first: Unplug the microwave before working on the control panel.

Step-by-step checks:

  • 1. Test all keys: Note which keys fail; if failures are in a pattern (row/column), the membrane is likely at fault.
  • 2. Inspect for damage: Look for cracks, bubbles, or discoloration on the keypad surface.
  • 3. Reseat ribbon cable: Remove the control panel and carefully disconnect and reconnect the keypad ribbon cable.
  • 4. Replace keypad: If issues persist, replace the membrane keypad or entire fascia assembly with a Grundig-compatible part.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Membrane Keypad Panel
Check Price on Amazon

We may earn a commission from links on this page.