Possible Causes
Loose mains connector inside unit, Faulty door switch causing brief power loss, Loose control PCB power connector, Failing line filter
How to Fix / Troubleshooting
Safety first: Unplug the microwave before inspection.
Step-by-step checks:
- 1. Observe behavior: Note if the display flickers when gently wiggling the power cord or tapping the cabinet.
- 2. Inspect mains connections: With the cabinet removed, check the power cord entry, line filter, and connectors to the control PCB. Tighten and reseat as needed.
- 3. Check door switches: A shorting door switch can momentarily drop power. Test and replace any suspect switches.
If resets continue, the control PCB may have an internal fault and should be replaced.