Grundig
Display Module / Control PCB Fault
Microwave display is dim, flickering, or some segments are missing, but the unit still heats.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Aging LED/LCD display, Loose display connector, Failing display driver on control PCB, Voltage drop in low-voltage supply
How to Fix / Troubleshooting
Safety first: Unplug the microwave before accessing the control panel.
Step-by-step checks:
- 1. Check for moisture: Wipe the control panel and ensure no condensation is present.
- 2. Access control panel: Remove the panel and inspect the display connector. Reseat it firmly.
- 3. Inspect PCB: Look for cracked solder joints around the display and voltage regulator components.
If reseating connectors does not improve the display, the display module or entire control PCB may need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Display Module
Check Price on Amazon