Possible Causes

Aging LED/LCD display, Loose display connector, Failing display driver on control PCB, Voltage drop in low-voltage supply

How to Fix / Troubleshooting

Safety first: Unplug the microwave before accessing the control panel.

Step-by-step checks:

  • 1. Check for moisture: Wipe the control panel and ensure no condensation is present.
  • 2. Access control panel: Remove the panel and inspect the display connector. Reseat it firmly.
  • 3. Inspect PCB: Look for cracked solder joints around the display and voltage regulator components.

If reseating connectors does not improve the display, the display module or entire control PCB may need replacement.