Hisense
Start Circuit / Control Input Failure
Microwave display is on but pressing Start does nothing; timer does not count down.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective Start button on keypad,Stuck or unresponsive keypad membrane,Control PCB input circuit failure,Child lock feature enabled
How to Fix / Troubleshooting
Safety first: Unplug before cleaning the keypad.
Steps:
- Check for child lock: Look for a lock icon or LOC on the display. If present, disable the lock by holding the designated key (often Stop/Cancel or 0) for several seconds.
- Test other keys: Try setting the clock or using other functions. If only the Start key fails, the keypad is likely faulty.
- Clean keypad surface: Wipe with a slightly damp cloth (no dripping liquid) and then dry. Do not spray cleaner directly onto the panel.
- Power reset: Unplug for 5 minutes, then reconnect and test again.
If the issue persists:
- A technician may need to replace the control panel keypad or main control PCB.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Control Panel Keypad
Check Price on Amazon