E08
Hoover Low Voltage Power Supply Fault

Microwave shows E08 and will not start; turntable and light do not activate.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal line fuse, Failed low-voltage transformer or SMPS on control board, Shorted wiring harness, Faulty door filter board (noise filter)

How to Fix / Troubleshooting

Safety first: Unplug the microwave. Internal fuses and power components are connected directly to mains voltage.

User-level checks:

  • Verify that the wall outlet is supplying power by testing with another appliance.
  • Check that the plug and cord are not damaged.

Technician-level checks:

  • Remove the outer cover and locate the main line fuse near the power entry or noise filter board.
  • Test the fuse with a multimeter; if open, investigate for shorts before replacing.
  • Inspect the noise filter board and wiring for burn marks or melted insulation.
  • Check the low-voltage supply section on the control PCB (transformer or SMPS) for output voltages as per Hoover service data.

Note: Never bypass a blown fuse without finding the root cause. If you are not trained in mains-voltage electronics, contact a professional.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Line Fuse
Check Price on Amazon

We may earn a commission from links on this page.