E06
Ikea Keypad Stuck or Shorted Key Error

Microwave shows E06 and may not respond to some buttons or may start/stop unexpectedly.

Advertisements

Possible Causes

Worn membrane keypad, Liquid spill behind keypad, Damaged touch sensor circuit on PCB, Shorted keypad ribbon

How to Fix / Troubleshooting

Safety: Unplug the microwave before any disassembly.

Steps:

  • 1. Clean the keypad surface: Wipe the control panel with a slightly damp cloth and mild detergent, then dry thoroughly. Do not spray cleaner directly onto the panel.
  • 2. Check for stuck keys: Press each button individually and feel for normal travel. If any key feels stuck or does not click, the membrane may be failing.
  • 3. Power reset: Unplug for 10 minutes, then reconnect and test. If E06 reappears immediately, a key is likely shorted.
  • 4. Inspect keypad ribbon (DIYers): Remove the control panel and inspect the keypad ribbon cable for cracks, corrosion, or signs of liquid damage. Reseat the connector.

Resolution: Replace the membrane keypad or the entire control panel assembly with the correct IKEA/Whirlpool/Electrolux-compatible part if the fault persists.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Membrane Keypad
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements