E08
Ikea Inverter Board Fault (Inverter-Type Models)

Microwave shows E08 and stops heating; fan may run but no microwave energy is produced.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed inverter power board, Shorted magnetron drawing excessive current, Loose connections between inverter and control board, Overcurrent protection triggered

How to Fix / Troubleshooting

Danger: Inverter-based microwaves contain high-frequency high-voltage circuits that are extremely dangerous. Only trained technicians should service the inverter or magnetron.

User checks:

  • 1. Power reset: Unplug the microwave for 10–15 minutes to reset the inverter protection. Plug back in and test with a short heating cycle.
  • 2. Ventilation: Ensure vents are clear to prevent overheating of the inverter module.

Technician checks:

  • Inspect the inverter board for burn marks or bulging components.
  • Check the magnetron for shorts and verify correct connections.
  • Measure supply voltages to the inverter from the main control board.

Resolution: Replace the inverter board and/or magnetron with OEM-compatible IKEA parts. In many cases, both are replaced together to ensure reliability.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Inverter Power Board
Check Price on Amazon

We may earn a commission from links on this page.