F13
Indesit Cooling fan or airflow fault

Microwave displays F13 and may shut down or refuse to start after prolonged use, especially on grill or convection settings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed cavity cooling fan motor, Blocked air vents, Fan blade obstruction, Faulty fan triac or relay on PCB

How to Fix / Troubleshooting

Safety first: Unplug the microwave and allow it to cool before inspection.

  • Step 1 – Check external ventilation: Ensure that the installation meets Indesit clearance requirements. Remove any items blocking the side, rear, or top vents.
  • Step 2 – Listen for fan operation: During a cooking cycle, you should hear the cooling fan running. If the fan is silent and F13 appears, suspect a fan fault.
  • Step 3 – Inspect fan (advanced): Remove the outer cabinet and locate the cooling fan (usually near the magnetron or at the rear). Check for debris or insulation blocking the blades.
  • Step 4 – Test fan motor: With the unit unplugged, spin the fan by hand; it should move freely. Measure motor resistance and check for an open circuit. Replace the fan if defective.
  • Step 5 – Check fan control on PCB: If the fan is good but never receives power, the control board's fan relay or triac may be faulty and the board may need replacement.

Warning: Do not operate the microwave with the cover removed or with a non‑functional cooling fan.