E10
Logik Door Lock / Latch Alignment Error

Microwave shows E10 and beeps repeatedly; door may appear closed but unit refuses to run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Misaligned door hinges, Worn or broken door latch hooks, Deformed door frame, Faulty door sensing switch on latch board

How to Fix / Troubleshooting

Safety: Unplug the microwave before adjusting hinges or removing panels.

Steps:

  • 1. Inspect door alignment: Check that the door sits square in the opening and that the gap around the door is even. If the door sags, gently lift it while closing to see if E10 clears.
  • 2. Check latch hooks: Open the door and inspect the plastic latch hooks on the door edge. If they are cracked, bent, or loose, they may not fully engage the interlock switches.
  • 3. Clean latch area: Remove any grease or food buildup around the latch openings in the cabinet that could prevent full engagement.
  • 4. Hinge screws: Tighten any loose hinge screws (accessible from the side or behind the trim on some Logik models). Do not overtighten to the point of distorting the door.
  • 5. Replace latch assembly: If the hooks are damaged, replace the door latch assembly with a Logik-compatible part. If the door sensing switch on the latch board is faulty, replace the switch or latch board as a unit.

Never attempt to bypass door safety switches; this is extremely dangerous and illegal in many regions.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Door Latch Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements