Microwave interior light, fan, and turntable run when door is closed, even without pressing START.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Danger: This is a serious safety fault. The microwave may generate microwaves with the door closed but without user command. Unplug immediately.
Steps (for technicians/competent DIYers only):
- 1. Do not use the microwave: Leave it unplugged until repaired.
- 2. Inspect door switches: Check that the common (COM), normally open (NO), and normally closed (NC) terminals are wired correctly according to the Logik wiring diagram.
- 3. Test switches: Use a multimeter to verify that switches change state correctly when the door opens/closes.
- 4. Check control relay: If switches are correct, the main power relay on the control PCB may be stuck closed and the board should be replaced.
Due to the safety implications, this repair is best handled by a professional.
Repair Difficulty
Required Part
We may earn a commission from links on this page.