F9
Midea Door Interlock Logic Error

Microwave shows F9; may not start or may shut down with a fault beep.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect state of door switches (monitor switch fault), Miswired door switch harness, Failed door monitor switch, Control board detecting unsafe door condition

How to Fix / Troubleshooting

Safety first: Unplug the microwave. Door interlock circuits are critical safety components; do not bypass them.

Step-by-step checks (experienced DIYers):

  • 1. Inspect door operation: Ensure the door closes firmly and evenly. Listen for multiple clicks from the interlock switches.
  • 2. Access interlock assembly: Remove the outer cabinet and control panel to reach the door switch bracket.
  • 3. Verify wiring: Compare the wiring to the schematic on the unit's label. Ensure the monitor switch, primary, and secondary switches are wired correctly.
  • 4. Test switches: Use a multimeter to test each switch for proper open/closed operation with the door open and closed. Replace any faulty switches.
  • 5. Reassemble and test: After replacing switches, reassemble and test. If F9 persists, the control board's door logic circuit may be defective.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Door Switch Kit (Primary/Secondary/Monitor) for Midea Microwave
Check Price on Amazon

We may earn a commission from links on this page.