F5
Miele Door Switch / Door Interlock Fault

Microwave stops mid-cycle and displays F5; may also fail to start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Misaligned door latch hooks, Failed primary or secondary door microswitch, Broken door latch bracket, Loose wiring at door switch assembly

How to Fix / Troubleshooting

Safety first: Unplug the microwave before inspecting the door mechanism. Do not operate the unit with the cover removed or with door switches bypassed.

  • Check door closure: Ensure the door closes fully and evenly. Look for obstructions, warped door, or damaged door seals.
  • Inspect latch hooks: Open the door and inspect the plastic latch hooks that engage the interlock switches. If they are cracked, loose, or misaligned, the switches may not actuate correctly.
  • Test door operation: Gently press on the door while starting a program. If the unit starts or stops when pressure is applied, the door switches or latch alignment are suspect.
  • Inspect switches (advanced): With the outer cover removed and power disconnected, locate the door interlock switch cluster. Check for loose mounting screws, bent actuator levers, or burned connectors.
  • Replace faulty switches: Test each microswitch with a multimeter for proper open/closed operation when the door is opened/closed. Replace any switch that does not change state reliably. If the latch bracket is damaged, replace the entire door latch assembly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Door Interlock Switch Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements